Reset the plane function – HEIDENHAIN iTNC 530 (340 49x-04) ISO programming User Manual
Page 488

488
9 Programming: Special Functions
9.2 The PLANE F
unction: Tilting the W
o
rk
ing Plane (Sof
tw
ar
e
O
ption
1
)
Reset the PLANE function
Show the soft-key row with special functions
Select special TNC functions: Press the
SPECIAL TNC FUNCTIONS soft key.
Select the PLANE function: Press the TILT
MACHINING PLANE soft key: The TNC displays the
available definition possibilities in the soft-key row.
Select the Reset function. This internally resets the
PLANE
function, but does not change the current axis
positions.
Specify whether the TNC should automatically move
the rotary axes to the default setting (MOVE or TURN) or
not (STAY) (see “Automatic positioning: MOVE/TURN/
STAY
(entry is mandatory)” on page 502).
To terminate entry, press the END key.
Example: NC block
N25 PLANE RESET MOVE ABST50 F1000 *
The PLANE RESET function resets the current PLANE
function—or an active Cycle 19—completely (angles = 0
and function is inactive). It does not need to be defined
more than once.