12 Test Run and Program Run
12.9 A
d
aptiv
e
F
e
ed Contr
o
l Sof
tw
a
re
Option (AFC)
Proceed as follows to select and, if required, edit the
<name>.H.AFC.DEP
file:
Select the Program Run, Full Sequence mode of
operation.
Shift the soft-key row.
Select the table of AFC settings.
Make optimizations if required.
You can also edit the <name>.H.AFC.DEP file in the Programming and
Editing mode of operation. If necessary, you can even delete a
machining step (entire line) there.
Note that the <name>.H.AFC.DEP file is locked against
editing as long as the NC program <name>.H is running.
The TNC then displays the data in the table in red.
The TNC removes the editing lock if one of the following
functions has been executed:
M02
M30
END PGM
In order to edit the <name>.H.AFC.DEP file, you must first
set the file manager so that the TNC can display
dependent files (see “Configuring PGM MGT” on page
637).