4 pr ogr am run – HEIDENHAIN iTNC 530 (340 49x-04) ISO programming User Manual

Page 593

Advertising
background image

HEIDENHAIN iTNC 530

593

12.4 Pr

ogr

am Run

To go to the first block of the current program to start a block scan,
enter GOTO “0”.

To select block scan, press the BLOCK SCAN soft key.

Start-up at N:

Enter the block number N at which the

block scan should end.

Program:

Enter the name of the program containing

block N.

Repetitions:

If block N is located in a program section

repeat, enter the number of repetitions to be
calculated in the block scan.

To start the block scan, press the machine START

button.

Contour approach (see following section).

If you are working with nested programs, you can use
MP7680 to define whether the block scan is to begin at
block 0 of the main program or at block 0 of the last
interrupted program.

With the 3-D ROT soft key, you can switch the coordinate
system between tilted, non-tilted and active tool axis
direction in order to move to the start-up position.

If you want to use the block scan feature in a pallet table,
select the program in which a mid-program startup is to be
performed from the pallet table by using the arrow keys.
Then press the RESTORE POS AT N soft key.

The TNC skips all touch probe cycles in a mid-program
startup. Result parameters that are written to from these
cycles might therefore remain empty.

The M142/M143 functions are not permitted during a mid-
program startup.

If you perform a mid-program startup in a program
containing M128, then the TNC performs any
compensation movements necessary. The compensation
movements are superimposed over the approach
movement.

Advertising