3 disassembling and mounting the ventilation grids, Disassembling and mounting the ventilation grids – SMA SC 500CP XT Installation User Manual

Page 42

Advertising
background image

Danger to life due to electric shock or electric arc if live components are touched

• Switch off the inverter and wait at least 15 minutes before opening it to allow the capacitors to discharge

completely.

Disconnect the inverter (see Section 6, page 36).

Disassembling the protective covers

Requirements:

The panels must be disassembled (see Section 7.2.1, page 40).

Procedure:

• Disassemble the protective covers.

Mounting the protective covers

1. Tighten all protective covers (torque: 5 Nm).

2. Ensure that the protective covers are firmly in place.

7.2.3

Disassembling and Mounting the Ventilation Grids

Disassembling the ventilation grids

1. Release the screws of the right-hand ventilation grid.

2. Pull the lower side of the right-hand ventilation grid forwards to

remove it.

3. Release the screws of the left-hand ventilation grid.

7 Periodic Actions

SMA Solar Technology AG

Operating Manual

SCCPXT-IA-E4-en-44

42