2 safety, 1 intended use, Safety – SMA SC 500CP XT Installation User Manual

Page 8: Intended use, 2safety

Advertising
background image

2

Safety

2.1

Intended Use

The Sunny Central is a PV inverter which converts the direct current generated in the PV modules into grid-compliant
alternating current. An external MV transformer fitted downstream feeds the generated alternating current into the
utility grid.

The product is suitable for indoor and outdoor use.

The enclosure complies with degree of protection IP54. The inverter is classified under Class 4C2 as per
EN 60721-3-4 and is suitable for operation in a chemically active environment.

The maximum permissible DC input voltage of the inverter must not be exceeded.

The inverter must only be operated in conjunction with a suitable MV transformer.

• The MV transformer must be designed for voltages that arise during pulsed mode of the inverter.

• For the Sunny Central 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT the maximum voltage to

ground is: ±1,450 V

• For the Sunny Central 850CP XT /900CP XT the maximum voltage to ground is: ±1,600 V

• Do not connect more than one inverter to one winding of the MV transformer.

• The neutral conductor on the low-voltage side of the MV transformer must not be grounded.

You can find further information on suitable transformers in the Technical Information "Requirements for Medium-
Voltage Transformers and Transformers for Internal Power Supply for the Sunny Central series CP XT and CP-JP and for
Sunny Central Storage".

Do not deactivate or modify settings that affect grid management services without first obtaining approval from the grid
operator.

Use this product only in accordance with the information provided in the enclosed documentation and with the locally
applicable standards and directives. Any other application may cause personal injury or property damage.

Alterations to the product, e.g. changes or modifications, are only permitted with the express written permission of
SMA Solar Technology AG. Unauthorized alterations will void guarantee and warranty claims and usually void the
operation permit. SMA Solar Technology AG shall not be held liable for any damage caused by such changes.

Any use of the product other than that described in the Intended Use section does not qualify as appropriate.

The enclosed documentation is an integral part of this product. Keep the documentation in a convenient place for
future reference and observe all instructions contained therein.

All work on the product must only be performed using appropriate tools and in compliance with the ESD protection
regulations.

Suitable personal protective equipment is to be worn by all persons working on or with the product.

Unauthorized persons must not operate the product and must be kept at a safe distance from the product.

The product must not be operated with open covers or doors.

The product must not be opened when it is raining or when humidity exceeds 95%.

The product must not be operated with any technical defects.

The type label must remain permanently attached to the product.

2 Safety

SMA Solar Technology AG

Operating Manual

SCCPXT-IA-E4-en-44

8

Advertising