7 sunny central 800cp-us/ca – SMA SC 500CP-US User Manual

Page 104

Advertising
background image

17  Technical Data

SMA America, LLC

104

SCCP-US-IA-US_en-41

Installation Manual

17.7 Sunny Central 800CP-US/CA

Input Data

Output Data

Power Consumption

Dimensions and Weight

Efficiency

Maximum altitude above mean sea level, MSL

6,562 ft. (2,000 m)

Supply air flow and quality

1766 SCFM (3,000 m

3

/h), Class 4S2

MPP voltage range

570 V

DC

to 820 V

DC

Maximum DC voltage

1,000 V

DC

Maximum DC current

1,600 A

DC

Max. array short circuit current

2,596 A

DC

Number of DC inputs*

* Only in the inverter option with DC fuses single phase

9

DC overvoltage category

II

Continuous AC power at +122°F (+50°C)

800 kVA

Continuous AC power at +104°F (+40°C)

832 kVA

Continuous AC power at +77°F (+25°C)

880 kVA

AC current at +122°F (+50°C)

1,283 A

AC

AC current at +104°F (+40°C)

1,334 A

AC

AC current at +77°F (+25°C)

1,411 A

AC

Nominal AC voltage ± 10%

360 V

AC

Nominal power frequency

60 Hz

Power frequency range

60 Hz [50 Hz]

Power factor cos φ

59.3 Hz to 60.5 Hz [49.3 Hz to 50.5 Hz]

Current THD

< 5% (with respect to IEEE 1547)

AC overvoltage category

IV

Self-consumption in operation

< 1,800 W

Standby consumption

< 150 W

Control supply voltage

See nameplate in the connection area of the control circuit

Width x height x depth

8 ft. 4.87 in x 7 ft. 5.45 in x 3 ft. 1.64 in.

(2,562 mm x 2,272 mm x 956 mm)

Weight

4,123 lb (1,870 kg)

Maximum efficiency

98.68%