12  Parameters

Operating Manual

SCxxxHE-20-BE-BEN111210

101

ErrLevGr1

*

Sensitivity of error
detection for group 1
Parameter exists for
all six groups

24 sensitive

50 min ‒ 10%

32 regular

24 regular

50 min ‒ 14%

24 insensitive

50 min ‒ 18%

32 sensitive

35 min ‒ 10%

32 regular

35 min ‒ 13%

32 insensitive

35 min ‒ 16%

64 sensitive

15 min ‒ 7%

64 regular

15 min ‒ 9%

64 insensitive

15 min ‒ 10%

ComBaud

*

Baudrate

1 200 Baud

19 200

Baud

**

4 800 Baud
9 600 Baud

19 200 Baud
38 400 Baud
57 600 Baud

DevFunc

*

Manages the Sunny
String-Monitors

AutoDetect_

SSMU

Searches for and
deletes Sunny String-
Monitors that have
already been
detected

0

DetectSSMU

Retry

Only searches for
undetected Sunny
String-Monitors

DelAll_SSMU

Deletes all detected
Sunny String-
Monitors

Factory

Resets all parameters
to their default
settings

These parameters are only visible after the installer password has been entered.

** 

If the PV plant is equipped with a Sunny String-Monitor Controller, the baud rate of all components must be set to

19 200 baud.

Name

Description

Value/Range

Explanation

Default

value