12 Parameters

12.1 Sunny Central

12.1.1 Power limitation

Name

Description

Value/Range

Explanation

Default

value

Plimit

*

Device's rated
output power

550 kW

SC 500HE-20

700 kW

SC 630HE-20

792 kW

SC 720HE-20

836 kW

SC 760HE-20

880 kW

SC 800HE-20

Pmax

**

Limitation of Sunny
Central's rated
output power

0 kW … 550 kW SC 500HE-20

550 kW

0 kW … 700 kW SC 630HE-20

700 kW

0 kW … 792 kW SC 720HE-20

792 kW

0 kW … 836 kW SC 760HE-20

836 kW

0 kW … 880 kW SC 800HE-20

880 kW

P-WMod

**

Procedure selection
for active power
limitation

Off

Limits active power to
"Pmax"

Off

WCtlCom

Limits active power via
Power Reducer Box

WCnst

Limits active power in
kW via the "P-W"
parameter

WCnstNom

Limits active power in %
via the "P-Wnom"
parameter

WCnstNomAnIn Limits active power in %

on the analog input

WCnstNomDigIn Limits active power on

the digital input
This procedure is not
supported

Advertising