7 Transmission Interface

YASKAWA ELECTRIC SIEP C730600 62B 1000-Series Option SI-ET3 Technical Manual

23

‹

Application Layer Specifications

The data format for the application layer conforms to the MECHATROLINK-III command specifications for standard
inverter profile.

SI-ET3 has the following main commands and sub-commands.

Table 10 Main Commands

Table 11 Sub-Commands

The sub-commands can be used only when the 64-byte data transmission (F6-21 = 0) has been selected. If a conflict
occurs between a request for a main command and a request for a sub-command, the request for the main command is
processed. If either a main command or a sub-command is already being processed, the command being processed is
given priority. If an INV_CTL main command and an INV_I/O sub-command conflict, the sub-command is given
priority.

For details on command formats, refer to

MECHATROLINK-III Commands on page 24

.

Table 12

shows the combination of main commands and sub-commands.

Table 12 Main Commands and Sub-Commands

Note: CMD_ALM = BH (sub-command combination error) will result if a main command and sub-command conflict with one

another.

Code

[HEX]

Name

Function

00

NOP

No Operation Command

01

PRM_RD

Read Parameter Command

02

PRM_WR

Write Parameter Command

03

ID_RD

Read ID Number Command

04

CONFIG

RAM Write and EEPROM Write Command

05

ALM_RD

Read Alarm and Warning Command

06

ALM_CLR

Clear Alarm and Warning Command

0D

SYNC_SET

Start Synchronous Communications Command

0E

CONNECT

Connect Command

0F

DISCONNECT

Disconnect Command

50

INV_CTL

Inverter Operation Control Command

Code

[HEX]

Name

Function

00

NOP

No Operation Command

01

PRM_RD

Read Parameter Command

02

PRM_WR

Write Parameter Command

05

ALM_RD

Read Alarm and Warning Command

51

INV_I/O

Inverter I/O Control Command

Code

[HEX]

Main Command

Sub-Command

NOP (00H)

PRM_RD (01H) PRM_WR (02H) ALM_RD (05H) INV_I/O (51H)

00

NOP

OK

OK

OK

OK

OK

01

PRM_RD

OK

OK

OK

02

PRM_WR

OK

OK

OK

03

ID_RD

OK

OK

OK

OK

OK

04

CONFIG

OK

05

ALM_RD

OK

06

ALM_CLR

OK

0D

SYNC_SET

OK

OK

OK

OK

OK

0E

CONNECT

OK

0F

DISCONNECT

OK

50

INV_CTL

OK

OK

OK

OK

OK

Advertising