Table 20, Invcmd_io command – Yaskawa SI-ET3 User Manual

Page 36

Advertising
background image

9 Main Command

36

YASKAWA ELECTRIC SIEP C730600 62B 1000-Series Option SI-ET3 Technical Manual

„

INVCMD_IO Command

Table 20 SEL_REF Reference Data Codes

Table 21 SEL_MON Monitor Data Codes

10

External fault (EF0)

1: External fault input (EF0)

11

Clear the fault history

1: Clear fault history

12

External base block reference

1: External base block reference ON

16

Multi-function input terminal 3

Multi-function input terminal S3
0: Multi-function input terminal S3 is OFF
1: Multi-function input terminal S3 is ON

17

Multi-function input terminal 4

Multi-function input terminal S4
0: Multi-function input terminal S4 is OFF
1: Multi-function input terminal S4 is ON

18

Multi-function input terminal 5

Multi-function input terminal S5
0: Multi-function input terminal S5 is OFF
1: Multi-function input terminal S5 is ON

19

Multi-function input terminal 6

Multi-function input terminal S6
0: Multi-function input terminal S6 is OFF
1: Multi-function input terminal S6 is ON

20

Multi-function input terminal 7

Multi-function input terminal S7
0: Multi-function input terminal S7 is OFF
1: Multi-function input terminal S7 is ON

21

Multi-function input terminal 8

Multi-function input terminal S8
0: Multi-function input terminal S8 is OFF
1: Multi-function input terminal S8 is ON

Vender Specific

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

Not used

Vender Specific

bit 15

bit 14

bit 13

bit 12

bit 11

bit 10

bit 9

bit 8

Not used

Vender Specific

bit 23

bit 22

bit 21

bit 20

bit 19

bit 18

bit 17

bit 16

Not used

bit 31

bit 30

bit 29

bit 28

Vender Specific

bit 27

bit 26

bit 25

bit 24

Reserved (0)

Not used

Selection Code

Monitor Name

Contents

0

Nothing Selected

1

Torque Compensation

Unit: 0.1%

2

Analog Output Terminal 1 Output

Enabled when H4-01 = 000

3

Analog Output Terminal 2 Output

Enabled when H4-01 = 000

4

Terminal Output

5

PID Setpoint

Unit: 0.01%

6

Pulse Output

Unit: 1 Hz

7

V/f Gain

8

Not used

9

Control Selection Setting

Bit 1: PID setpoint enabled

Selection Code

Monitor Name

Contents

0

Nothing Selected

1

Motor Speed

Displayed in U1-05 and determined by o1-03.

2

Torque Reference (Monitor)

Displayed in U1-09 (0.1%).

3

Not used

4

Frequency Reference

Displayed in U1-01 and determined by o1-03.

5

Analog Input Terminal A2

Displayed in U1-14 (0.1%).

Bit

Name

Description

Advertising