Disconnect: 0fh (release connection command), Inv_ctl: 50h (inverter operation control command), Table 17 – Yaskawa SI-ET3 User Manual

Page 34

Advertising
background image

9 Main Command

34

YASKAWA ELECTRIC SIEP C730600 62B 1000-Series Option SI-ET3 Technical Manual

Table 17 COM_MOD

Table 18 COM_MOD Bits

‹

DISCONNECT: 0FH (Release Connection Command)

The DISCONNECT command is used to release the connection. When this command is completed, the communication
phase shifts to communication phase 1.

‹

INV_CTL: 50H (Inverter Operation Control Command)

The INV_CTL command is used to set the drive operation signals, speed references, and so on. Units for speed reference
and output frequency are determined by parameter o1-03. This command can be used in communication phases 2 and 3.

2

CMD_STAT

Refer to

Command Status (CMD_STAT) on page 24

.

3
4

VER

The value set in the command

5

COM_MOD

The value set in the command

6

COM_TIM

The value set in the command

7

PROFILE_TYPE

The value set in the command

8

Reserved (0)

Not used

x
x

31

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

SUBCMD

0

0

0

DTMODE

SYNCMODE

0

Bit

Name

Value

Description

SUBCMD

Sub-command setting

0

Sub-command disabled

1

Sub-command enabled

DTMODE

Data transfer method

0

Single transmission

SYNCMODE

Synchronization setting

0

Performs synchronous communication

1

Performs asynchronous communication

DISCONNECT Command

Byte

Command

Description

0

DISCONNECT (0FH)

Command code

1

Reserved (0)

Not used

x
x

31

DISCONNECT Response

Byte

Response

Description

0

DISCONNECT (0FH)

Command code

1

Reserved (0)

Not used

x
x

31

INV_CTL Response

Byte

Response

Description

0

INV_CTL (50H)

Command code

1

WDT

Watchdog data

CONNECT Response

Byte

Command

Description