Follower dev sel, Pg mon ch select, Position p gain – Yaskawa G7 Drive User Manual

Page 10: Position i time

Advertising
background image

Date: 03/31/09, Rev: 09-03

Page 10 of 30

TM.G7SW.064

4.1 Parameters (continued)

Control Mode *1

Paramete

r

Numb

er

Modbu

s

Addre

ss

Parameter Name

Digital Operator

Display

Description

Ran

ge

Default

Cha

nge Duri

ng

Run

V/f

V/f w/ P

G

Open Lo

op

Vector 1, 2

F

lux Vector

P2-07 610H

Follower

Deviation

Selection

Follower Dev Sel

Selects the follower drive
action when the position error
exceeds the P2-06 setting.

0: No Detection

The drive continues to run.

1: Alarm

The drive continues to run
and an FDEV alarm flashes
on the digital operator.

2: Fault (Coast to Stop)

The FDEV fault is
displayed, the drive fault
contact is activated, and the
motor coasts to a stop.

0 ~ 2

2

No

A

P2-08 611H

Encoder (PG)

Monitor Channel

Selection

PG Mon Ch

Select

Selects which input encoder
signal is sent to the PG
monitor output when using a
dual channel PG option card
(PG-W2, PG-Y2, or PG-Z2).

0: Channel 1

Encoder 1 is sent to the
monitor output.

1: Channel 2

Encoder 2 is sent to the
monitor output.

0 ~ 1

1

Yes A A

A

A

P2-09 612H

MOP Adjustment

Memorization at

Power Off

MOP Mem @

Pwr Off

Determines if the MOP gear
adjustment is memorized when
the follower drive loses power.

0: Disabled

MOP adjustment is not
memorized at power down.

1: Enabled

MOP adjustment is
memorized at power down.

0 ~ 1

0

No A A

A

A

P3-01 614H

Position P Gain

Position P Gain

Sets the proportional gain of
the position regulator PI loop.

Note: ELS modes only.

0.00 ~

100.00

5.00 Yes – – – A

P3-02 615H

Position I Time

Position I Time

Sets the integral time of the
position regulator PI loop.

Note: ELS modes only.

0.00 ~

50.00

sec

0.00 Yes – – – A

*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”, – = Not Available.