Yaskawa G7 Drive User Manual

Page 23

Advertising
background image

Date: 03/31/09, Rev: 09-03

Page 23 of 30

TM.G7SW.064

For the ELS - Sign Run mode (P1-01 = 5), the functionality of the Communication Advance/Retard Counts
Register is adjusted in the same way. With a forward run command, a positive value in the register will
move the follower drive in the absolute positive direction and a negative value will move the follower drive in
the absolute negative direction, while with a reverse run command these directions are switched. The
direction the follower is moved by the Advance/Retard command is always with respect to the run command
direction. The functionality of Advance/Retard for both P1-01 = 4 (Standard ELS) and P1-01 = 5 (ELS - Sign
Run) is shown in Figure 4.

When the drive is put into local mode (digital input or keypad button) or when the drive is given a forward or
reverse jog command, the frequency reference is switched back to standard frequency reference and the
selected Accel / Decel times are used.

The table below shows the direction of the Follower depending on the direction of the Master, P1-01 setting,
B1-04 (reverse operation prohibit selection) setting, and the forward run / reverse run digital input signal.


Follower Rotation Direction for Various Settings and Master Direction

P1-01 = 1

P1-01 = 2

P1-01 = 3

P1-01 = 4

P1-01 = 5

B1-04

(Reverse

Operation)

Digital

Input

Signal

Master:

FWD

Master:

REV

Master:

FWD

Master:

REV

Master:

FWD

Master:

REV

Master:

FWD

Master:

REV

Master:

FWD

Master:

REV

FWD FWD REV FWD NONE FWD FWD FWD REV FWD REV

B1-04 = 0

Enabled

REV REV FWD NONE REV REV REV FWD REV REV FWD

FWD FWD NONE FWD NONE FWD FWD FWD NONE

b

FWD

NONE

b

B1-04 = 1

Disabled

REV NONE NONE NONE NONE NONE NONE NONE

a

NONE

b

NONE

a

NONE

b

a: Inability to follow causes position error accumulation and potential FDEV faults in these conditions.
b: Inability to follow does not cause position error accumulation in these conditions unless P1-09 = 1, due to
the way the drive handles the B1-04 = 1 condition.

Figure 4 below outlines the follower direction and Advance/Retard behavior for P1-04 settings and forward /
reverse run command selections.

FWD

FWD

Adv

Ret

REV

REV

Ret

Adv

REV

Adv

Ret

FWD

REV

FWD

Adv

Ret

FWD

FWD

Adv

Ret

REV

REV

Ret

Adv

FWD

REV

FWD

Adv

Ret

REV

Ret

Adv

FWD Run Command

REV Run Command

P1-01 = 4

P1-01 = 5

Master

Follower

Master

Follower

Figure 4: Follower Direction and Advance/Retard Behavior

Advertising