Position error, Position p out, Position i out – Yaskawa G7 Drive User Manual

Page 15: Position pi out

Advertising
background image

Date: 03/31/09, Rev: 09-03

Page 15 of 30

TM.G7SW.064

4.2 Monitors (U1-XX) (continued)

Control Mode *1

Monitor Num

ber

Modbu

s Add

ress

Monitor Name

Digital Operator

Display

Description

Scaling for

Multi-

function

Analog

Output

Terminals

FM and AM

(H4-01, H4-

04)

Unit

V/f

V/f w/ P

G

Open Lo

op

Vector 1, 2

Flu
x

Vector

U1-96 726H

Position Error

Position Error

Displays the position
error between the
master and follower
encoders in quadrature
follower encoder counts.

Note: ELS modes only.

100% =

Maximum

Output

Frequency

(E1-04)

1

Count

*2

– – – Q

*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”, – = Not Available.
*2: Unit is dependent on the setting of the Position Units Selection (P1-10). When the position error is greater
than the maximum value that can be displayed, the digital operator will flash “OVER” in place of the U1-96 data.
When reading by network communication (register 726H), the unit is fixed at quadrature encoder counts.

4.2 Monitors (U1-XX) (continued)

Control Mode *1

Monitor Num

ber

Modbu

s Add

ress

Monitor Name

Digital Operator

Display

Description

Scaling for

Multi-

function

Analog

Output

Terminals

FM and AM

(H4-01, H4-

04)

Unit

V/f

V/f w/ P

G

Open Lo

op

Vector 1, 2

Flu
x

Vector

U1-97 727H

Position Regulator

P Output

Position P Out

Displays the
proportional gain
contribution of the
position PI regulator.

Note: ELS modes only.

100% =

Maximum

Output

Frequency

(E1-04)

0.01% – – – Q

U1-98 728H

Position Regulator

I Output

Position I Out

Displays the output of
the integrator of the
position PI regulator.

Note: ELS modes only.

100% =

Maximum

Output

Frequency

(E1-04)

0.01% – – – Q

U1-99 729H

Position Regulator

PI Output

Position PI Out

Displays the output of
the position PI regulator.

Note: ELS modes only.

100% =

Maximum

Output

Frequency

(E1-04)

0.01% – – – Q

*1: Access Level (A1-01): Q = “Quick Start”, A = “Advanced”, F = “Factory”, – = Not Available.

Advertising