Master marker fq, Slave marker fq, Master cts/5ms – Yaskawa G7 Drive User Manual

Page 13: Slave cts/5ms

Advertising
background image

Date: 03/31/09, Rev: 09-03

Page 13 of 30

TM.G7SW.064

4.2 Monitors (U1-XX)

Control Mode *1

Monitor Num

ber

Modbu

s Add

ress

Monitor Name

Digital Operator

Display

Description

Scaling for

Multi-

function

Analog

Output

Terminals

FM and AM

(H4-01, H4-

04)

Unit

V/f

V/f w/ P

G

Open Lo

op

Vector 1, 2

Flu
x

Vector

U1-56 079H

Master Marker

Frequency

Master Marker Fq

Displays the frequency
of the master alignment
input pulse.

Note: This monitor
should be used for
testing and debugging
only, not for
measurement.

Note: ELS modes only.

N/A

Hz –

Q

U1-57 07AH

Slave Marker

Frequency

Slave Marker Fq

Displays the frequency
of the follower marker
alignment input pulse.

Note: This monitor
should be used for
testing and debugging
only, not for
measurement.

Note: ELS modes only.

N/A

Hz –

Q

U1-58 079H

Master

Counts/5ms

Master Cts/5ms

Displays the number of
quadrature encoder
counts per 5ms scan
from the master drive.

Note: ELS modes only.
Note: This monitor is
should be used only to
confirm that encoder
counts are being
received.

100% =

Counts/5ms

at Maximum

Output

Frequency

(E1-04)

Counts - - - Q

U1-59 07AH

Slave Counts/5ms

Slave Cts/5ms

Displays the number of
quadrature encoder
counts per 5ms scan
from the follower drive.

Note: ELS modes only.
Note: This monitor
should be used only to
confirm that encoder
counts are being
received.

100% =

Counts/5ms

at Maximum

Output

Frequency

(E1-04)

Counts - - - Q

Advertising