Mop adjust increase, Mop adjust decrease, Mop adjust reset – Yaskawa G7 Drive User Manual

Page 17: Position error reset, Position regulator integral reset, Align by pulse (alignment), Save displacement, Disable displacement error

Advertising
background image

Date: 03/31/09, Rev: 09-03

Page 17 of 30

TM.G7SW.064

4.3 Multi-function Digital Input Settings (H1-XX) (continued)

Control Mode *1

Setting

Name

Description

V/f

V/f w/ P

G

Open Lo

op

Vector 1, 2

F

lux Vector

84

MOP Adjust Increase
Closed: The MOP ratio adjustment is increased. See P2-02 and P2-09.

85

MOP Adjust Decrease
Closed: The MOP ratio adjustment is decreased. See P2-02 and P2-09.

86

MOP Adjust Reset
Closed: The MOP ratio adjustment is reset to zero. See P2-02 and P2-09.

87

Position Error Reset
Closed: Position regulator error is reset to zero.

Note: ELS modes only.

88

Position Regulator Integral Reset
Closed: Position regulator integrator is reset to zero.

Note: ELS modes only.

89

Align by Pulse (Alignment)
Closed: Alignment function is enabled and the drive will keep the number
of quadrature follower encoder counts (displacement) between the master
and follower alignment inputs equal to the displacement reference.

Note: ELS modes only.

– – – √

8A

Save Displacement
Closed: At the transition from open to closed, the current Displacement
Reference value (which can be seen in the Displacement Reference
monitor U1-94) will be saved to the Initial Alignment Displacement
Parameter (P4-01). The data will survive a power loss.

Note: ELS modes only.
Note: Since this command saves the data into non-volatile RAM, do not
continuously use this function. The drive’s storage RAM could fail causing
drive failure.

– – – √

8B

Disable Displacement Error
Closed: Displacement error will not be corrected. However, if the Align by
Pulse (Alignment) digital input (H1-XX = 89) is closed, the displacement
feedback will still be calculated and displayed (U1-95), but the follower
drive will not correct for any displacement error. This input is useful for
troubleshooting and testing.

Note: ELS modes only.

– – – √

*1: √ = Available, – = Not Available.