6 - 78

YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions

(b) Example

(c) Control conditions

Designation of the size of the data table (number of bytes) (IPSH X)

Designate the size of the data table by the number of bytes.

Designation of the start address of the data table (APSH#XXXX)

Designate the start address of the data table

The data table can be created at any place.

Designation of the input data address (APSH#XXXX)

Designate the address where the data to be searched is stored.

Designation of the output data address (APSH#XXXX)

When the specified data are found (R1 = 0), the number in the table where the
found data are stored is output. Designate the address where that number is stored.