Yaskawa YASNAC PC NC PLC Programming Manual User Manual
Page 30
5 - 7
YASNAC PCNC PLC Programming Manual Chapter 5: Address Numbers And Map
(7) Addresses of Timers (#1300 to #1399 and #1700 to #1799)
For the timers, addresses #1300 to #1399 and #1700 to #1799 are assigned.
•
One address number corresponds to a timer.
Example:
The number of available timers and timer setting units are indicated below.
Table 5.1 Available Timer and Setting Units
•
An example of a timer symbol is indicated below.
Example:
Address No.
Timer Type
Number of Timers
#1700 to #1709, #1760 to #1769
#1300 to #1309, #1360 to #1369
1 = 8 msec
40
#1710 to #1729, #1790 to #1799
#1310 to #1329, #1390 to #1399
1 = 0.1 sec
60
#1730 to #1749, #1780 to #1789
#1330 to #1349, #1380 to #1389
1 = 50 msec
60
#1750 to #1759, #1350 to #1359
1 = 1 sec
20
#1770 to #1773, #1370 to #1373
1 = 1 min.
8