YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions
•
Designation of the data table size (the number of bytes) (IPSHXXXX)
Designate the size of the data table by the number of bytes.
•
Designation of the start address of the data table (APSH#XXXX)
Designate the start address of the data table.
The data table can be created at any place.
•
Designation of the input data address (APSH#XXXX)
Designate the address where the data to be searched are stored.
•
Designation of the output data address (APSH#XXXX)
When the specified data are found (R1 = 0), the number in the table where the
found data are stored is output. Designate the address where that number is stored.
•
Designation of the data size (BYT)
BYT = 0: The data stored in the data table are 1-byte data.
BYT = 1: The data stored in the data table are 2-byte data.
•
Execution command (ACT)
ACT = 0: The DSCH instruction is executed.
ACT = 1: The DSCH instruction is not executed.
•
Reset (RST)
RST = 0: Error output R1 is not reset.
RST = 1: Error output R1 is reset.
•
Error output (R1)
R1 = 0:
The search data are found.
R1 = 1:
The search data are not found.