Yaskawa YASNAC PC NC PLC Programming Manual User Manual
Page 67

6 - 31
YASNAC PCNC PLC Programming Manual Chapter 6: PLC Instructions
(b) Format
(c) Explanation
•
After the execution of the COR instruction, the contents of R1 and R2 remain
unchanged.
•
A ST contact must be entered before the COR instruction.
•
The COR instruction is executed in intervals of “4 × n” msec while the ST contact
is ON.
(d) Example
(22)MOV (Move Register) RR after operation: RR-
(a) Function
The function transfers the content of the register R1 to register R2 when the ST contact
is ON (RR = 1).
The content of the register R1 remains unchanged before and after the execution of the
instruction.
If the ST contact is OFF (RR = 0), the MOV instruction is not executed.
(b) Format
(c) Explanation
•
A ST contact must be entered before the MOV instruction.
•
The MOV instruction is executed in intervals of “4 × n” msec while the ST contact
is ON.
A B Paradym31 Variable Name
A B Paradym31 Variable Name