d) Example

(6) SBI (Subtract Immediate) RR after operation: RR-

(a) Function

The instruction subtracts the specified numeric value from the content of the register and
stores the result to the register when the ST contact is ON (RR = 1). If the ST contact is
OFF (RR = 0), the instruction is not executed.

The RR content remains unchanged before and after the execution of the SBI instruction.

(b) Format

(c) Explanation

•

An ST contact must be entered before the SBI instruction.

•

The SBI instruction is executed in intervals of “4 × n” msec while the ST contact is
ON.

•

There is no function to detect underflow. Make sure that “numeric value contents of
register”.

(d) Example

(7) ANI (AND Immediate) RR after operation: RR-

(a) Function

The instruction executes AND between the specified numeric value and the content of the
register and stores the result to the register when the ST contact is ON (RR = 1). If the ST
contact is OFF (RR = 0), the instruction is not executed.

The RR content remains unchanged before and after the execution of the ANI instruction.

B A Paradym31 Variable Name