2.4 Cable Specifications and Peripheral Devices

25

The following table shows types of cables. It is used in conjunction with the preceding
tables.

The following table specifies the appropriate cables for CN1 and CN2 digital torque amplifier
connectors. Wire sizes were selected with the expectation of three cables per bundle, at an
ambient temperature of 40°C, at the rated current level.

Cable Type

Temperature Rating of Conductor

°C

Name

Composition

PVC

Standard polyvinyl chloride cable

IV

600V PVC cable

60

HIV

Temperature-resistant vinyl cable

75

Connector Name

Signal

Description

Specification

Control I/O Signal

Connector

CN1

Cable

Use twisted pair or shielded twisted pair wire.

Applicable wire

(AWG): 24, 26, 28, 30

Finished cable

Dimension

Φ 0.63 (Φ16.0) maximum

PG Signal

Connector

CN2

Cable

Use Yaskawa cable, or shielded twisted pair wire.

Applicable wire

(AWG): 24, 26, 28, 30

Use 22 AWG [0.0005in

2

(0.34mm

2

)] for the encoder power supply and 26

AWG [0.0002 in

2

(0.14mm

2

)] for other signals. These conditions permit

wiring distances up to 65.6ft (20m).

Finished cable

Dimension

Φ 0.27 (Φ6.8) maximum

Advertising