4.1 Torque/Force Control

41

4. Description of Functions

4.1 Torque/Force Control

This is the torque/force control-dedicated mode.
This control mode inputs the torque/force reference from CMD-IN (CN1-3 & CN1-4).

4.2 Protection Sequence Design

This section describes the methods for integrating a protective sequence for safety purposes
using I/O signals from the digital torque amplifier.

Servo Alarm Output

The basic method for continuing alarm-related “output signals” is shown below.
Prepare an external 24V usage power source. No 24V power source is integrated in the digital
torque amplifier. The photocoupler output signal is handled as follows:

The output is “ON” when the digital torque amplifier detects an error.

Output

ALM+

 

CN1-34

Servo Alarm Output

Output

ALM- CN1-35

Signal ground for servo alarm
output

C M D -IN

Amplifier

C N 1-3

S G

C N 1-4

CMD-IN

CN1-3

CN1-4

SG

D igital Torque A m plifier

CN1-34

CN1-35

ALM+

ALM-

24V P ow er

+24V

0V

P hotocoupler

Photocoupler Output per
Output
Max. Usage voltage: DC30V
Max. Usage Current: :DC50mA

MAX 50mA

Digital Torque Amplifier