3.2 Rotary Motor Mounting

30

Before Mounting

The shaft end is treated with a rust-preventative agent. Before mounting the motor, wipe
off this rust-preventative agent with a cloth soaked in thinner.
When removing the rust-preventative agent, be sure that the thinner does not contact any
other parts of the servomotor.

Storage Temperature

Store the servomotor within the temperature range below when storing without electrical
feed.

-20 ~ +60°C Temperature Range

Mounting Location

The SGM□H servomotor is intended for use indoors. Use in an environment meeting the
following conditions.

• Indoors, in a location free from corrosive or explosive gas.

• A location with good ventilation, with little dust, grime, or steam

• A location with an ambient temperature between 0~40°C

• A location with a relative humidity of 20%~80%, no condensation

• A location easy to inspect and clean

Important

R ust-
preventative
A gent