3.2 Rotary Motor Mounting

30

Before Mounting

The shaft end is treated with a rust-preventative agent. Before mounting the motor, wipe
off this rust-preventative agent with a cloth soaked in thinner.
When removing the rust-preventative agent, be sure that the thinner does not contact any
other parts of the servomotor.

■

Storage Temperature

Store the servomotor within the temperature range below when storing without electrical
feed.

-20 ~ +60°C Temperature Range

■

Mounting Location

The SGM□H servomotor is intended for use indoors. Use in an environment meeting the
following conditions.

• Indoors, in a location free from corrosive or explosive gas.

• A location with good ventilation, with little dust, grime, or steam

• A location with an ambient temperature between 0~40°C

• A location with a relative humidity of 20%~80%, no condensation

• A location easy to inspect and clean