Phase power specification (sgdg-10gt, sgdg-15gt), 5 standard connection examples 27, Sgdg- □□ gt digital torque amplifier – Yaskawa LEGEND Digital Torque Amplifier User Manual

Page 38

Advertising
background image

2.5 Standard Connection Examples

27

3-Phase Power Specification (SGDG-10GT, SGDG-15GT)

L1

U

L2

V

W

L3

L1C

L2C

CN1-26

CN1-27

CN1-13

CN1-34

ALM+

/

-

ON

CN1-14

CN1-35

ALM-

CN1-7

RUN+

/DBOFF

CN1-15

CN1-10

RUN-

CMD-IN

CN1-3

CN1-20

PAO

GND

CN1-4

CN1-21

/PAO

CN1-22

PBO

CN1-23

/PBO

CN1-24

PCO

CN1-25

/PCO

3.3

KΩ

MC1

DB OFF

SV ON

ALM

run

PA

PB

PC

A/D

RY2

RY1

Motor

PG

CN2

B1

B2

B3

Noise Filter

Power

OFF

Power

ON

MC1

Surge

Supressor

3.3

KΩ

24V~12V

Torque/

Force

Reference

Encoder

Divided

Output

SN75ALS174 or similar product

SGDG-

□□

GT Digital

Torque Amplifier

Emergency

Stop

MC1

RY10

RY10

24V~12V

Power

 

90V~253V Ac

SV ON

 

3

DB_OFF

FG

FG

*

* For single-phase

applications, use terminals
L1 + L3 for the main
power connection.

Advertising