Yaskawa LEGEND Digital Torque Amplifier User Manual

Page 76

Advertising
background image

Appendix B: Installation Conditions for EMC Directives

65

Noise Filter for Brake Power Supply

FN2070-6/07 (Made by Schaffner) for servomotors of 0.4kW or less.

Cable Specifications

Shielded cables should be used for the following cables:

AC power input line cable (between the power supply and the noise filter)
Servomotor cable (between the digital torque amplifier and the servomotor)
Encoder cable (between the digital torque amplifier and the servomotor)
Controller cable (between the digital torque amplifier and the controller)

Recommended Ferrite Cores

Shielded Box

A shielded box, a closed metallic enclosure, should be used for shielding electromagnetic
interference. The structure of the box should allow the main body, door, cooling unit, etc., to
be attached to the ground. The box opening should be as small as possible.

Cable Name

Ferrite Cores

Manufacturer

Controller Cable

ESD-SR-25

Tokin

Encoder Cable

Servomotor Cable

400W or lower

ESD-SR-25

Tokin

1kW or higher

PC40T90×13.5×74

TDK

Advertising