3.3 Digital Torque Amplifier Installation

34

3.3 Digital Torque Amplifier Installation

The SGDG digital torque amplifier is a base-mounted digital torque amplifier. Mount it
properly according to the following cautionary items as mistakes in the mounting method can
lead to failure of the unit.

■

Storage Conditions

Store the digital torque amplifier within the temperature range below when storing
without electrical feed.

Temperature Range: -20~ +85°C

■

Mounting Conditions

Location

The following points should be kept in mind with regard to the mounting location.

Installation

Conditions

Cautions on Mounting

Mounted in a Control
Panel

Design the control panel size, digital torque amplifier
installation, and cooling method so that the ambient
temperature of the digital torque amplifier does not exceed
55

°C

.

Mounted Near a Heat-
Generating Object

Suppress the temperature rise due to radiated heat and
convection from the heat-generating object so that the
ambient temperature of the digital torque amplifier does
not exceed 55

°C

.

Mounted Near a
Vibration Source

Attach vibration-preventative brackets to the digital torque
amplifier mounting surface so that the vibrations are not
communicated to the digital torque amplifier.