4 switch settings – Yaskawa LEGEND Digital Torque Amplifier User Manual

Page 48

Advertising
background image

3.4 Switch Settings

37

3.4 Switch Settings

SW1 Function Selection Switch (dip switches)

SW2 Linear Scale Pitch Setting (rotary switch)

The default setting is 0 (0

μ

m).

Switch No.

Function

At OFF

At ON

Default Setting

1

Status After DB Stop

During Base Block

Release DB after

motor stop

Continue DB after

motor stop

ON

2

Torque Reference Filter

No

Yes

ON

3

Input Power Selection

DC-Power Input

Compatible

AC-Power Input

Compatible

ON

4

Linear Scale Polarity

Reversal

B-phase progression:

U, V, W direction

A-phase progression:

U, V, W direction

ON

(enabled only when

linear motor is used)

5

Regen Overload Alarm or

Warning

No

Yes

ON

6

Feedback Pulse

B-phase Reversal

Reversed

Not reversed

ON

7

Command Direction

Reversal

Reversed

Not reversed

ON

8

Not used

ON

Setting

Linear Scale Pitch Setting

Setting

Linear Scale Pitch Setting

0*

0

μ

m

8

Not used

1

2

μ

m

9

Not used

2

4

μ

m

A

Not used

3

20

μ

m

B

Not used

4

40

μ

m

C

Not used

5

800

μ

m

D

Not used

6

1000

μ

m

E

Not used

7

Not used

F

Not used

Advertising