4 switch settings – Yaskawa LEGEND Digital Torque Amplifier User Manual

Page 48

Advertising
background image

3.4 Switch Settings

37

3.4 Switch Settings

■

SW1 Function Selection Switch (dip switches)

■

SW2 Linear Scale Pitch Setting (rotary switch)

*

The default setting is 0 (0

μ

m).

Switch No.

Function

At OFF

At ON

Default Setting

1

Status After DB Stop

During Base Block

Release DB after

motor stop

Continue DB after

motor stop

ON

2

Torque Reference Filter

No

Yes

ON

3

Input Power Selection

DC-Power Input

Compatible

AC-Power Input

Compatible

ON

4

Linear Scale Polarity

Reversal

B-phase progression:

U, V, W direction

A-phase progression:

U, V, W direction

ON

(enabled only when

linear motor is used)

5

Regen Overload Alarm or

Warning

No

Yes

ON

6

Feedback Pulse

B-phase Reversal

Reversed

Not reversed

ON

7

Command Direction

Reversal

Reversed

Not reversed

ON

8

Not used

ON

Setting

Linear Scale Pitch Setting

Setting

Linear Scale Pitch Setting

0*

0

μ

m

8

Not used

1

2

μ

m

9

Not used

2

4

μ

m

A

Not used

3

20

μ

m

B

Not used

4

40

μ

m

C

Not used

5

800

μ

m

D

Not used

6

1000

μ

m

E

Not used

7

Not used

F

Not used

Advertising