5.2 Digital Torque Amplifier Inspection

54

5.2 Digital Torque Amplifier Inspection

Digital torque amplifier inspection is summarized in the table below. Although there is no
need for daily inspection, perform inspections at least once per year.

Component Replacement Timeline

The components in the table below are subject to mechanical wear or degradation over
time. Inspect these periodically for purposes of preventative maintenance.
Digital torque amplifiers overhauled by Yaskawa are shipped with their system switches
returned to their factory default settings. Be sure to verify these switches before
operating.

Use Conditions

• Ambient Temperature: Yearly average 30

°

C

• Load Ratio: 80% or less

• Operation Rate: 20 hours or less per day

Table 5.2: Digital Torque Amplifier Inspection

Inspection

Item

Inspection

Period

Inspection Content

Measures Taken at

Error

Unit, Board

Cleaning

Once per year

minimum

There should be no grime,

dust, or oil on the unit.

Clean with air or cloth.

Loose Screws

Once per year

minimum

There should be no

looseness in the terminal

block and connector

mounting screws.

Tighten

Component Fault

in Unit or Board

Once per year

minimum

There should be no changes

in coloration due to heat,

damage, or wire breakage.

Consult Yaskawa.

Table 5.3: Periodic Inspection of Components

Component Name

Standard

Replacement

Period

Replacement Method, Other

Cooling Fan

4 ~ 5 Years

Replace with a new item.

Smoothing Capacitor

7 ~ 8 Years

Replace with a new item. (determine by

inspection)

Relays

Determine by inspection

Fuses

10 years

Replace with a new item.

Discharge Capacitor on

Printed Circuit Board

5 years

Replace with a new board. (determine

by inspection)