A.4 connecting the acroloop acr-8010 – Yaskawa LEGEND Digital Torque Amplifier User Manual

Page 71

Advertising
background image

Appendix A: Host Controller Connection Examples

60

A.4 Connecting the Acroloop ACR-8010

SGDG, CN1

3

CMD-IN

4

GND

20

PAO

21

PAO

22

PBO

23

PBO

24

PCO

25

PCO

26

SV ON5

ASIG-x

AGND-x

P*

OUT-y

CHAn

CHAn'

CHBn

CHBn'

MRKn'

CASE

P*

P*

P*

MRKn

33

GND

AGND

P*

P* = Twisted Pair
n = Axis Designation, 0, 1, 2...
x = Analog output number
y = Digital output number

LEGEND - Acroloop (ACR-8010), Minimum Servo Interface

Encoder type is Differential Line Driver (+5 Volt Outputs) so Pullups should be removed
Encoders 0-3 are on P1A connector
Encoders 4-7 are on P1B connector
ASIG-0 and AGND-0 through ASIG-7 and GND-7 are on P2 connector
AGND is on P2 connector
OUT-32 through OUT-63 are on P3 connector

Torque Reference should be

mapped to one of these

analog outputs

Servo on should be

mapped to one of these

digital outputs