4.5 Regenerative Resistor Selection

50

Connecting the JUSP-RG08D to the SGDG-01GT/SGDG-04GT

a) A regenerative unit has the following fault detection functions:

• Detecting disconnection in a regenerative resistor

• Detecting faults in a regenerative resistor

• Detecting overvoltage

b) When one of these fault detection functions operates, the internal alarm relay is

actuated. Then the circuit between output terminals C1 and C2 is opened.

c) When an external resistor is used, remove the shorting jumper between Y4 and Y5.

Then, connect the resistor between P/Y3 and Y4.

d) The resistance value of the external resistor should be 50

min.

SGDG-04GTY22P

Connect the regen resistor between terminals B1-B2 on the SGDG-04GTY22P digital
torque amplifier.

D

Amplifier

B1

B2

Regen Resistor

* The regen resistor is provided
by the customer.

SGDG-
04GTY22P