YASKAWA TOEP YAIL1E 02A YASKAWA AC Drive - L1000E Safety Precautions

‹

Installation Orientation and Spacing

WARNING! Fire Hazard. Provide sufficient cooling when installing the drive inside an enclosed panel or cabinet. Failure to comply

could result in overheating and fire. When drives are placed inside the same enclosure panel, install proper cooling to ensure air

entering the enclosure does not exceed 40

°C (104°F).

„

Installation Orientation

Install the drive upright as illustrated in

Figure 1

to maintain proper cooling.

Figure 1

Figure 1 Correct Installation Orientation

„

Installation Spacing

Figure 2

shows the installation distance required to maintain sufficient space for airflow and wiring.

Figure 2

Figure 2 Correct Installation Spacing

‹

Instructions on Installation

Eye bolts are used to install the drive or to temporarily lift the drive when replacing it. The drive can be installed in an
enclosure panel or on a wall. Do not leave the drive suspended by the wires in a horizontal or vertical position for long
periods of time. Do not transport the drive over long distances. Read the following precautions and instructions before
installing the drives.

WARNING! Crush Hazard. Be sure to observe the following instructions and precautions. Failure to comply could result in minor or

moderate injury and damage to the drive from falling equipment.

Before using wires to suspend the drive vertically and horizontally, make sure that the drive front cover,

terminal blocks and other drive components are securely fixed with screws.

Do not subject the drive to vibration or impact greater than 1.96 m/s

2

(0.2 G) while it is suspended by the

wires.

Do not overturn the drive while it is suspended by the wires.

Do not leave the drive suspended by the wires for long periods of time.

Only allow qualified personnel to operate a crane or hoist to transport the drive.

Use a dedicated lifter when transporting the drive by a lifter.

Only use vertical suspension to temporarily lift the drive during installation to an enclosure panel. Do not

use vertical suspension to transport the drive.

A – 50 mm (1.97 in.) minimum

C – 120 mm (4.72 in.) minimum

B – 30 mm (1.18 in.) minimum

D – Airflow direction

A

A

B

B

Side Clearance

Top/Bottom Clearance

C

C

D

D

PWR

LED MONITOR JVOP-184

RUN

DS1

DS2

RUN DS1 DS2

STATUS

READY
RUN
ALARM(RUN)
PGOH,LT
BB,HBB
EF,SE

Other Fault

OV,UV
OH,OL
OC,GF,SC,PGO
CPF,OFA,OFB,OFC

:LIGHT

:BLINK

:LIGHT OFF

PW

R

LED M

ONIT

OR JV

OP-18

4

RUN

DS1

DS2

RUN

DS1

DS2

STAT

US

READ

Y

RUN

ALARM

(RUN

)

PGOH

,LT

BB,H

BB

EF,SE

Othe

r Fau

lt

OV,U

V

OH,O

L

OC,G

F,SC,P

GO

CPF

,OFA

,OFB

,OFC

:LIGH

T

:BLIN

K

:LIGH

T O

FF

Advertising