Yaskawa AC Drive-L1000E Safety Precautions User Manual

Page 39

Advertising
background image

8 Troubleshooting

YASKAWA TOEP YAIL1E 02A YASKAWA AC Drive - L1000E Safety Precautions

39

CPF,OFA,OFB,OFC

oFC03 to oFC11

O

Option card error occurred at option port CN5-C

oFC12 to oFC17

O

oFC50

O

Encoder Option AD Conversion Error
Error with the A/D conversion level (VCC level), or A/D conversion timed out.

oFC51

O

Encoder Option Analog Circuit Error
Incorrect signal level (+2.5 V signal)

oFC52

O

Encoder Communication Timeout
Signal encoder timed out waiting to receive data

oFC53

O

Encoder Communication Data Error
Serial encoder CRC checksum error

oFC54

O

Encoder Error
Alarm reading EnDat absolute position data from encoder
(OR flag from EnDat error for overvoltage, undervoltage, etc.)

-

oPr

O

External Digital Operator Connection Fault

• The external operator has been disconnected from the drive.

Note: An oPr fault will occur when all of the following conditions are true:

• Output is interrupted when the operator is disconnected (o2-06 = 1).
• The Up/Down command is assigned to the operator (b1-02 = 0 and LOCAL has been

selected).

BB,HBB

bb

O

Baseblock
Drive output interrupted as indicated by an external baseblock signal.

Hbb

O

Safe Disable Circuit Fault Signal (H1-HC, H2-HC) Release
Both Safe Disable Input channels are open.

HbbF

O

Safe Disable Circuit Fault Signal (H1-HC, H2-HC) Release
One Safe Disable channel is open while the other one is closed.

EF,SE

EF

O

Up/Down Command Error
Both forward run and reverse run closed simultaneously for over 0.5 s.

EF0

O

O

Option Card External Fault
An external fault condition is present.

EF3

O

O

External fault (input terminal S3)
External fault at multi-function input terminal S3.

EF4

O

O

External fault (input terminal S4)
External fault at multi-function input terminal S4.

EF5

O

O

External fault (input terminal S5)
External fault at multi-function input terminal S5.

EF6

O

O

External fault (input terminal S6)
External fault at multi-function input terminal S6.

EF7

O

O

External fault (input terminal S7)
External fault at multi-function input terminal S7.

EF8

O

O

External fault (input terminal S8)
External fault at multi-function input terminal S8.

EF,SE

SE

O

MEMOBUS/Modbus Self Test Failed

SE1

O

Motor Contactor Response Error
Motor contactor does not respond within the time set to S1-10 (Run Command Delay
Time).

EF,SE

SE2

O

Starting Current Error
The output current was lower than 25% of the motor no-load current at start.

JVOP-184

Status Text

ALARM

FAULT

Fault/Alarm

Code

<1>

ALM FLT

Fault Name/Cause

Advertising