Control circuit input terminals – Yaskawa AC Drive-L1000E Safety Precautions User Manual

Page 27

Advertising
background image

5 Electrical Installation

YASKAWA TOEP YAIL1E 02A YASKAWA AC Drive - L1000E Safety Precautions

27

„

Control Circuit Input Terminals

Table 8

lists the input terminals on the drive. Text in parenthesis indicates the default setting for each multi-function

input.

Table 8 Control Circuit Input Terminals

Terminals A1 and A2 can accept a voltage signal to supply the speed reference to the drive.

Table 9

shows the parameter

settings and voltage levels required for each terminal.

Table 9 Analog Input Settings for Speed Reference Using Voltage Signals

Type

<1> Setting jumper S3 for an external power supply makes the wire jumper between terminals H1, H2, and HC ineffective. Remove the wire jumper

and connect an external power supply that can supply terminals H1, H2, and HC continuously.

No.

Terminal Name (Function)

Function (Signal Level) Default Setting

Page

Digital Inputs

S1

Up Command (Closed: Up, Open: Stop)

Photocoupler
24 Vdc, 8 mA
Use the wire link between terminals SC and SN or between SC
and SP to select sinking or sourcing, and to select the power
supply.

178

S2

Down Command (Closed: Down, Open: Stop)

S3

Multi-function input 1 (External Fault)

S4

Multi-function input 2 (Fault Reset)

S5

Multi-function input 3 (Multi-Step Speed
Reference 1)

S6

Multi-function input 4 (Multi-Step Speed
Reference 2)

S7

Multi-function input 5 (Multi-Step Speed
Reference 3)

S8

Multi-function input 6 (Not used)

Digital Input
Power Supply

SC

Multi-function input common

24 Vdc, 150 mA (only when DI-A3 is not used)
Use the wire jumper between terminals SC and SN or between SC
and SP to select sinking or sourcing, and to select the power
supply.

33

SN

0 V

SP

+24 Vdc

Safe Disable
Inputs

<1>

H1

Safe Disable input 1

24 Vdc, 8 mA
One or both open: Drive output disabled
Both closed: Normal operation
Internal impedance: 3.3 k

Ω

Off time of at least 1 ms
Set the S3 jumper to select sinking or sourcing, and to select the
power supply.

225

H2

Safe Disable input 2

HC

Safe Disable function common

Common for the Safe Disable function

Analog Inputs

+V

Power supply for analog inputs

10.5 Vdc (max allowable current 20 mA)

223

-V

Power supply for analog inputs

-10.5 Vdc (max allowable current 20 mA)

A1

Multi-function analog input 1 (Speed
reference bias)

-10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 k

Ω)

A2

Multi-function analog input 2 (Not used)

-10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 k

Ω)

AC

Analog input common

0 V

E (G) Ground for shielded lines and option cards

Terminal

Signal

Level

Parameter Settings

Notes

Signal Level

Selection

Function Selection

Gain

Bias

A1

0 to 10 Vdc

H3-01 = 0

H3-02 = 0

(speed reference bias)

H3-03

H3-04

-10 to +10

Vdc

H3-01 = 1

A2

0 to 10 Vdc

H3-09 = 0

H3-10 = 0

(speed reference bias)

H3-11

H3-12

-10 to +10

Vdc

H3-09 = 1

Advertising