4 Mechanical Installation

YASKAWA TOEP YAIL1E 02A YASKAWA AC Drive - L1000E Safety Precautions

9

4

Mechanical Installation

CAUTION! Crush Hazard. Carrying the drive by the front cover may cause the main body of the drive to fall, resulting in minor or

moderate injury. Always hold the case when carrying the drive.

‹

Installation Environment

Install the drive in an environment matching the specifications below to help prolong the optimum performance life of the
drive.

Table 3 Installation Environment

NOTICE: Avoid placing drive peripheral devices, transformers, or other electronics near the drive as the noise created can lead to

erroneous operation. If such devices must be used in close proximity to the drive, take proper steps to shield the drive from electrical

inteference.

NOTICE: Prevent foreign matter such as metal shavings and wire clippings from falling into the drive during installation. Failure to

comply could result in damage to the drive. Place a temporary cover over the top of the drive during installation. Remove the temporary

cover before startup, as the cover will reduce ventilation and cause the drive to overheat.

Environment

Conditions

Installation Area

Indoors

Ambient Temperature

IP00 enclosure with top protective cover: -10 to +40

°C (14 to 104°F)

IP00 enclosure: -10 to +50

°C (14 to 122°F)

Drive reliability improves in environments without wide temperature fluctuations.
When using the drive in an enclosure panel, install a cooling fan or air conditioner in the area to ensure that the air
temperature inside the enclosure does not exceed the specified levels.
Do not allow ice to develop on the drive.

Humidity

95% RH or less and free of condensation

Storage Temperature

-20 to 60

°C (-4 to 140°F)

Surrounding Area

Install the drive in an area free from:

• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight

Altitude

1000 m (3280 ft.) or lower, up to 3000 m (9842 ft.) with derating (Refer to

Altitude Derating on page 160

)

Vibration

10 to 20 Hz at 9.8 m/s

2

20 to 55 Hz at 5.9 m/s

2

(2A0018 to 2A0225 and 4A0009 to 4A0188) or 2.0 m/s

2

(2A0269 to 2A0432 and 4A0225 to

4A0260)

Orientation

Install the drive vertically to maintain maximum cooling effects.