Heat loss, Altitude derating, Notice – Yaskawa AC Drive-L1000E Safety Precautions User Manual
Page 53: 10 drive specifications
10 Drive Specifications
YASKAWA TOEP YAIL1E 02A YASKAWA AC Drive - L1000E Safety Precautions
53
Figure 24
Figure 24 Ambient Temperature and Installation Method Derating
Altitude Derating
The drive standard ratings are valid for an installation altitude up to 1000 m. If the altitude exceeds 1000 m both the drive
rated voltage and the rated output current must be derated for 1% per 100 m. The maximum altitude is 3000 m.
Heat Loss
NOTICE
Refer to the L1000E Quick Start Guide TOEPYAIL1E01 or Technical Manual SIEPYAIL1E01 for more information
regarding Heat Loss and for complete product instructions necessary for proper installation, set up, troubleshooting and
maintenance. The L1000E Series CD-ROM No. CD.L1E.01 packaged with the drive contains the L1000E Technical
Manual No. SIEPYAIL1E01 and additional L1000E Series manuals.
100
85
0
L8-35=2 : NEMA Type 1 Enclosure
L8-35=0 : IP00 Enclosure
-10
40
50
Drive Rating
(%)
L8-12
(Ambient temp : °C)