10 Drive Specifications

YASKAWA TOEP YAIL1E 02A YASKAWA AC Drive - L1000E Safety Precautions

53

Figure 24

Figure 24 Ambient Temperature and Installation Method Derating

„

Altitude Derating

The drive standard ratings are valid for an installation altitude up to 1000 m. If the altitude exceeds 1000 m both the drive
rated voltage and the rated output current must be derated for 1% per 100 m. The maximum altitude is 3000 m.

‹

Heat Loss

NOTICE

Refer to the L1000E Quick Start Guide TOEPYAIL1E01 or Technical Manual SIEPYAIL1E01 for more information
regarding Heat Loss and for complete product instructions necessary for proper installation, set up, troubleshooting and
maintenance. The L1000E Series CD-ROM No. CD.L1E.01 packaged with the drive contains the L1000E Technical
Manual No. SIEPYAIL1E01 and additional L1000E Series manuals.

100

85

0

L8-35=2 : NEMA Type 1 Enclosure

L8-35=0 : IP00 Enclosure

-10

40

50

Drive Rating

(%)

L8-12
(Ambient temp : °C)