8.1 Comments on Setup Wizard

8-3

8

8.1.2 Pop-up Help Menu

This section explains the contents of the pop-up help that will be displayed with the mouse
cursor located.

„

Module Configuration Window

The following pop-up help menu items will appear when the cursor is located on the icon of
each Module in the Setup Wizard 4: Module Configuration Window.

Item

Kind

Comment

Module
configu-
ration

Short/Long
rack

Set the rack for set the module.

Possible to set maximum 4 racks.

CPU

CPU module

This has to be set on the 1st rack.

EXIF

Module for the connecting between a module and a module

Required for setting more than 2 racks.

SVA1

Analog servo module

Possible to control the 4 axes.
This uses 2 slots.

SVA2

Analog servo module

Possible to control the 2 axes.

SVB1

Network digital servo module

Possible to control the 14 axes with MECHATROLINK.

PO

Pulse output module

Possible to control the 4 axes of the pulse motors.

AI

Analog input module

The analog input number are 8.

AO

Analog output module

The analog output number are 4.

CNTR

Counter module

The pulse input number are 4.

DI

Digital input module

The digital input number are 64.

DO

Digital output module

The digital output number are 64.

LIO

Local I/O module

This has 32 digital inputs and 32 digital outputs.

215IF

215 I/F module

Connectable to the CP-215 N to N communication.

217IF

217 I/F module

Serial I/F and possible to connect RS-232C, RS-485.

218IF

218 I/F module

ETHERNET protocol

216IF

DeviceNet module

Connect the DeviceNet module.

Advertising