3.2 Operation of Controller Configuration

3-11

3

2. 02:ch#2

This indicates SVB-CH2 in Setup Wizard 4: Module Configuration Window.

If this item is selected, detailed data on SVB-CH2 configuration allocations will be dis-
played.

MP920

The drop-down list of Servo Control Modules will display ††:SVB-01 models, the number
of which will be the same as that set in Setup Wizard 4: Module Configuration Window.

Note: Replace

††

with the Motion Module number in actual operation.

Motion Module numbers will be allocated automatically in numerical order (e.g., 01, 02, and
so on) to all Servo Modules set in Setup Wizard 4: Module Configuration Window.

The following illustration is an example of the settings.

When any Module is selected from the drop-down list, Module information on the corre-
sponding Module set in Setup Wizard 4: Module Configuration Window will be displayed.

MP930 or MP940

If the MP930 or MP940 Machine Controller is used, the box for Servo Control Module
selection will not be displayed.

The following Module information will be displayed.

INFO

Two SVB Modules exist, to which

Motion Module numbers 02 and 03

are allocated.