Yaskawa MPLoad Maker User Manual

Page 23

Advertising
background image

5 Creating .BAT File Executable from HDD

5.2 Creating .BAT File

23

8.

Set the transfer destination Machine Controller (Module).

< When Serial is selected as Port No. >
Unit No.: The value set in the setting dialog box of the port type selected in the Communication setting Dialog
Box is displayed. It is possible to change the value.
CPU No: Select 1.

< When the 218 communication module is selected as Port No. >
IP Address: The default setting 192 168 1 1 is displayed. Change the setting to the IP address of the transfer
destination 218IF Module.
CPU No.: Select 1.

< When MP2100 is selected as Port No. >
CPU No.: Select the CPU number of the transfer destination Machine Controller. Select a CPU number from the
CP numbers (CPU numbers) in the setting dialog box of the MP2100 (port type) selected in the Communication
setting
Dialog Box.

ΠSelecting a CPU number other than those in the Communication setting Dialog Box will generate an alarm at

execution of transfer.

< When USB is selected as Port No. >
Local Address : Select the USB port address of the transfer destination Machine Controller.

Advertising