User’s Manual of WGSW-20160HP/WGSW-24040HP series

338

The Page includes the following fields:

General Settings

Object

Description

•

Enable Loop

Protection

Controls whether loop protections is enabled (as a whole).

• Transmission Time

The interval between each loop protection PDU sent on each port. valid values

are 1 to 10 seconds.

•

Shutdown Time

The period (in seconds) for which a port will be kept disabled in the event of a

loop is detected (and the port action shuts down the port). Valid values are 0 to

604800 seconds (7 days). A value of zero will keep a port disabled (until next

device restart).

Port Configuration

Object

Description

•

Port

The switch port number of the port.

• Enable

Controls whether loop protection is enabled on this switch port.

• Action

Configures the action performed when a loop is detected on a port. Valid values

are Shutdown Port, Shutdown Port and Log or Log Only.

•

Tx Mode

Controls whether the port is actively generating loop protection PDU's, or

whether it is just passively looking for looped PDU's.

Buttons

: Click to save changes.

:

Click to undo any changes made locally and revert to previously saved values.