5 wiring the fault alarm contact – PLANET IGS-10020HPT User Manual

Page 43

Advertising
background image

User’s Manual

2.

Tighten the wire-clamp screws for preventing the wires from loosening.

1 2

3 4 5

6

DC

1 DC

2

Figure 2-18

6-Pin Terminal Block Power Wiring Input

Model Name

Positive (+) Pin

Negative (-) Pin

Input Voltage

IGS-10020MT

Pin 2 / 6

Pin 1 / 5

DC 12~48V, AC 24V

IGS-10020PT/HPT

Pin 1 / 5

Pin 2 / 6

DC 48V

IGS-10020HPT

Pin 1 / 5

Pin 2 / 6

DC 48V

IGS-10080MFT

Pin 1 / 5

Pin 2 / 6

DC 12~48V, AC 24V

IGS-12040MT

Pin 1 / 5

Pin 2 / 6

DC 12~72V, AC 24V

1. The wire gauge for the terminal block should be in the range of 12 ~ 24 AWG.

2. When performing any of the procedures like inserting the wires or tightening the wire-clamp screws,

make sure the power is OFF to prevent from getting an electric shock.

2.1.5 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle (3 & 4) of the terminal block connector as the picture shows below. Inserting the wires,

the Industrial Managed Switch will detect the fault status of the power failure, or port link failure (available for managed model).

The following illustration shows an application example for wiring the fault alarm contacts

Insert the wires into the fault alarm contacts


43