16 digital input / output – PLANET IGS-10020HPT User Manual

Page 92

Advertising
background image

User’s Manual

4.2.16 Digital Input / Output

Digital Input

allows user to log external device (such as industrial cooler) dead or alive or something else. System will log a

user customized message into system log and syslog, and issue SNMP trap or issue an alarm E-mail.

Digital Output

allows user to monitor the switch port and power, and let system issue a high or low signal to an external device

(such as alarm) when the monitor port or power has failed. The Configuration screen in

Figure 4-2-19

appears.

Figure 4-2-19

Windows File Selection Menu Popup

The page includes the following fields:

Object

Description

Enable

Check the Enable checkbox to enable Digital Input / output function.

Uncheck the Enable checkbox to disable Digital input / output function.

Condition

As Digital Input:

Allows user to select High to Low or Low to High. This means a signal received

by system is from High to Low or From Low to High. It will trigger an action that

logs a customize message or issue the message from the switch.

As Digital Output:

Allows user to select High to Low or Low to High. This means

that when the

switch is power-failed or port-failed, then system will issue a High or

Low signal to an external device such as an alarm.

Event Description

Allows user to set a customized message for Digital Input function alarming.


92

Advertising
This manual is related to the following products: