Scrolling led status indicators – ProSoft Technology MVI56E-GSC/ GSCXT User Manual

Page 71

Advertising
background image

MVI56E-GSC ♦ CompactLogix or MicroLogix Platform

Diagnostics and Troubleshooting

Enhanced Generic ASCII Serial Communication Module

User Manual

ProSoft Technology, Inc.

Page 71 of 140

May 9, 2014

To begin the display of communications data, start the Data Analyzer. When the
Data Analyzer is running, you should see something like this.

The <R+> means that the module is transitioning the communications line to a
transmit state.

All characters shown in <> brackets are characters being sent out by the module.

The <R-> shows when the module is done transmitting data and is now ready to
receive information.

All characters shown in [ ] braces are information being received from another
device by the module.

After capturing traffic for a minute or two, stop the Data Analyzer.

3.6

Scrolling LED Status Indicators

The scrolling LED display indicates the module’s operating status as follows:

Advertising