13. Close the separation roller cover until you hear it click into place.

Note:

If you are not able to close the cover, the roller is not installed correctly. Remove the roller and

reinstall it, then try to close the cover again.

14. Close the scanner cover.

15. Connect any disconnected cables.

16. Plug in the AC adapter and turn on the scanner.

17. Reset the roller counter.

Resetting the Scanner Roller Counter

Parent topic:

Cleaning and Transporting Your Scanner

Related tasks

Changing the Scanner Position (DS-32000)

Resetting the Scanner Roller Counter

When you replace the scanner rollers or perform regular cleaning, reset the scanner roller counter so
you know when you may need to perform maintenance again.

1.

Press the

home button, if necessary, and select

Scanner Maintenance

.

2.

Select a maintenance task:

• If you replaced the pickup rollers, select

Pickup Roller Replacement

.

• If you replaced the separation rollers, select

Separation Roller Replacement

.

• If you cleaned the interior of the scanner, select

Regular Cleaning

.

3.

Select

Reset the Number of Scans

.

Note:

If the administrator has set an administrator password and locked the settings, you will need to

enter the password.

4.

Select

Yes

to reset the roller counter.