Error messages
Symptom
Cause
Action
Resume Data Error
Importing the resume data failed.
The product started with the previous or default settings.
Restart the product, and check whether the same error
occurs.
Preset Data Error
Importing the preset data failed.
The preset data is the one that was successfully imported
last time or the default.
Restart the product, and check whether the same error
occurs.
Library Data Error
Importing the EQ library data failed.
The product started with the previous or default settings.
Restart the product, and check whether the same error
occurs.
Audio-Technica LINK Connection
Error
An error occurred in communication with the ATDM-
0604a connected via Audio-Technica LINK.
The operation of Audio-Technica LINK was stopped.
Check for any network connection problem.
Audio-Technica LINK OFF
The Audio-Technica LINK was canceled, and its operation
was stopped.
Check for any network connection problem.
Detect Exceeded Link Units
The number of ATDM-0604a units available for
connection has been exceeded.
The operation of Audio-Technica LINK was stopped.
Check the number of units connected.
Detect Multi Primary Units
Multiple ATDM-0604a parent units detected.
The operation of Audio-Technica LINK was stopped.
Set only one ATDM-0504a unit as the primary.
Detect Ring Connection
A ring connection was detected.
The operation of Audio-Technica LINK was stopped.
Do not connect units in a ring pattern. Be sure to leave one
of the LINK terminals of the ATDM-0604a at both ends of the
connection unconnected.
Network Communication Error
A network communication error occurred.
Check for any network connection problem.
An IP command communication error occurred.
Access from Non Permitted Device
A device not permitted to access was connected.
Check for any network connection problem.
File Import Failed
Importing the preset file failed.
• Check whether the file format is correct.
• The network connection may have been disconnected.
File Export Failed
Exporting the preset file failed.
The network connection may have been disconnected.
Failed
An unknown system failure occurred.
Perform the operation again, and check whether the same
error occurs.
Please turn power OFF.
An error occurred during the firmware update.
Restart the product, and check whether the same error
occurs.
Data acquisition error.
Acquisition of data via web remote failed.
Perform the operation again, and check whether the same
error occurs.
USB Disconnected
The USB connection with the PC is not established.
• Check whether the USB connection with the PC is proper.
• Connect the USB to another PC, and check whether the
same error occurs.
Synchronous Disconnect
Synchronization with the PC failed.
• Check whether the USB connection with the PC is proper.
• Connect the USB to another PC, and check whether the
same error occurs.
Cannot COPY
The data cannot be copied because the EQ preset is full.
Check whether there is space in the EQ preset.
Copying of the bands in static state to the 12-band EQ
failed.
The bands for which EQ is set to OFF on the 12-band EQ
side are to be copied. Check the settings.