Panasonic KX-TD500 User Manual

Page 105

Advertising
background image

System

Programming Guide

105

Parameter

28. Trunk hunting mode

Default

Forced

Value Range

1.

Forced

2.

Loop Detection

Description/Function

Specifies the trunk hunting mode.

1.

Forced
The system seizes a trunk line whether or not loop current is
detected from the local CO.

2.

Loop Detection
The system seizes a trunk line after detecting loop current from
the local CO.

Reference

• 3.2

Trunk Group (P/G)

Parameter

29. Card CODEC

Default

Mu Law

Value Range

1.

Mu Llaw

2.

A Law

Description/Function

Specifies the PCM (Pulse Code Modulation) conversion mode of
KX-T96xxx series trunk and extension cards.

Note

•

This setting is required only when XMX (for Mexico) type
KX-T96xxx series trunk and extension cards are installed in
the system. In this case, select "A Law."

Reference

None

Parameter

30. Net CODEC

Default

Mu Law: [HK], A Law: Others

Value Range

1.

Mu Law

2.

A Law

Description/Function

Specifies the type of PCM (Pulse Code Modulation) conversion
mode compatible with the Digital Network to which the system is
connected.

Note

•

The change of this parameter is activated after resetting the
system.

Reference

None