Programming Error Messages

Programming Guide

341

E0012

Another maintenance device is connected.
There are three ways to access the PBX: (1) By PC System Programming, (2) by
Remote System Programming, or (3) by User Programming. But only one at a time.

E0013

Please reconnect after the PBX becomes on-line or off-line completely.
Tried to connect the PC before the PBX became on-line or off-line completely.
Please try after the off-line indicator (on the top shelf) goes off (on-line) or turns on and
off (off-line).

E0014

Please enter profile name.
Attempted to save remote connection parameters without profile name.

E0015

Failed: Saving of remote connection parameters.
Remote connection parameters are saved as a file ("TD500.INI") in the Microsoft
Windows operating system directory. The TD500 maintenance programme creates this
file automatically if the file does not exist. However, if the file exists and it is damaged,
you will get this error message. You must either repair the damage (using a text editor)
or rename it as a different file.

E0016

Failed: Deletion of remote connection parameters.
Deletion of remote connection parameters failed because file "TD500.INI" is damaged.
Please refer to the description of E0015.

E0017

Failed: Reading of remote connection parameters.
Reading of remote connection parameters failed because file "TD500.INI" is damaged.
Please refer to the description of E0015.

E0018

There is not enough space on your hard disk (or floppy) to save the system data.
Download is incomplete because there is not enough space on your hard disc (or
floppy) to save the system data.

E1001

You have exceeded the shelf limit of PT ports.
There is a limit of 128 PT ports per shelf when using PLC, HLC, DLC or DHLC cards.
Please de-assign one card and try again.

E1002

You have exceeded the system limit of trunk ports.
There is a limit of 192 trunk ports per system when using LCOT, GCOT, T1, PCOT,
RCOT, DID, DID-2W, DID-MFC, ELCOT, E1, E&M, BRI, PRI23 or PRI30 cards.
Please de-assign one card and try again.

E1003

You have exceeded the system limit of extension ports.
There is a limit of 448 extension ports per system when using DLC, PLC, HLC, SLC,
SLC-M, OPX, DLC, DHLC, or ESLC cards. Please de-assign one card and try again.

E1004

You have exceeded the system limit of trunk + extension ports.
There is a limit of 512 trunk + extension ports per system, using trunk and extension
cards. Please de-assign one card and try again.

E1005

You have exceeded the system limit of DISA cards.
There is a limit of 8 DISA cards per system.