Installation of fireplace, Caution – Hearth and Home Technologies C-40 User Manual

Page 15

Advertising
background image

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 15

A. Install the Outside Air Kit

This fireplace will operate correctly only if adequate ventila-

tion is provided to allow proper draft to the fireplace system.

See Section 2.
Using an outside air kit must be used for combustion to mini-

mize the effects of negative pressure within the structure.

We recommend you utilize the shortest duct run to optimize

the performance of the outside air kit. The outside air kit inlet

should be positioned in a manner that will not allow snow,

leaves, etc. to block the inlet. In some installations the air

duct may need to be run vertically. In such an installation, a

3 ft (914 mm) height difference must be maintained from the

top of the uppermost chimney section to the outside com-

bustion air inlet. See Figure 16.1 on page 16.
See Figure 17.1 on page 17 for proper placement of outside

air inlet.
The outside air kit is installed on the right hand side of the

fireplace. See Figure 15.1 for handle location/operation.

4

Installation of Fireplace

Figure 15.1

Outside Air Installation

1. Cut a 6 in. (152 mm) hole in outside wall to accommodate

air piping. The outside air is located on top, auxiliary

convection air intake is located on the bottom. See Figure

15.1.

2. Use 6 in. (152 mm) metal flex or rigid piping (not supplied)

to directly connect outside air to fireplace intake. Insulate

the pipe to prevent frost condensation.

3. Use the supplied termination caps.
4. Seal between the wall and the pipe with silicone to prevent

moisture penetration and air leaks.

5. Seal between the termination cap and the house with

silicone to prevent air infiltration.

NOTE: A control knob allows you control of the outside air

inlet. Use of outside air for combustion is required to

conserve heated air within the structure and to provide

make up air to keep the fireplace venting properly.

IMPORTANT!

TURN COUNTER-CLOCKWISE TO “OPEN”

POSITION.

OUTSIDE AIR KNOB MUST BE IN THE “OPEN” POSI-

TION TO OPERATE FIREPLACE PROPERLY.

MAY BE CLOSED WHEN NOT IN USE TO PREVENT

COLD AIR INFILTRATION.

Termination Cap

supplied with

fireplace

6 in. (152mm) rigid

or flex pipe

Open/Close

Knob for

outside air

CLOSE

OPEN

CAUTION

Sharp Edges
• Wear protective gloves

and safety glasses during

installation.