Warning, E. non-combustible facing material installation – Hearth and Home Technologies C-40 User Manual

Page 42

Advertising
background image

Page 42

Heatilator • Constitution EPA Fireplace • 480-1091C

November 11, 2008

TOOLS NEEDED: Powered drill with #2 Phillips head bit;

caulking gun.

1in. (25mm) OVERLAP

Metal strips 2 in. (51mm) under edge of

Fireplace and Hearth Extension and 2 in.

(51mm) on both side of fireplace opening.

Nail or screw metal strips in place.

Seal with

non-combustible

sealant

Top

Board

Bottom

Board

Side

Board

Side

Board

Tabla superior

Tabla lateral

Tabla inferior

Tabla lateral

Aplique Super Calstick en el extremo

FIGURA A

FIGURA B Instalación completa del material

de revestimiento incombustible

#7014-063, 5 de enero de 2006 Página 1 de

1

Apply bead of

Super Calstick to

edge here

1. Secure the fireplace to the floor or wall framing studs at

a minimum of two attachment points to prevent further

movement of the fireplace. The same holes and L brack-

ets that attached the fireplace to the pallet may be used

to secure the fireplace to the sub flooring by using a mini-

mum of two 1/4 in. x 2 in. lag bolts or equivalent. Refer

to Figure 42.1

and install the two metal hearth strips at

this time.

NOTE: All boards are pre-drilled for your convenience.

Boards MUST be attached in the following order:

bottom, top, and then the two sides.

2. Attach the bottom board to the bottom of the outer fire-

place can with enclosed screws, ensuring the board is

centered.

3. Center and attach the top board to the outer can and

framing members.

4. Using the Super Calstick, run a light bead (1/8 in. mini-

mum) on the butt edges of the top board. See Figure

42.2

.

5. Ensuring the top of the side pieces and the top board

align, attach the side pieces to the outer can and framing

members.

6. Use a wet or dry towel or a soft brush to remove any

dust or dirt from facing material. Apply a non-combustible

adhesive to attach tile, stone or other non-combustible fin-

ishing materials per manufacturer’s instructions.

7. The non-combustible Super Calstick may be used for

sealing between the fireplace and the hearth extension.

Refer to Figure 42.3.

E. Non-Combustible Facing Material
Installation

Figure 42.1

Figure 42.2

Figure 42.3

Figure 42.4

Complete installation

Risk of Fire.
• Follow these instructions exactly.
• Facing materials must be installed properly

to prevent fire.

• No materials may be substituted

without authorization by Hearth & Home

Technologies.

WARNING

Advertising