B. sl-300 series ceiling/roof thimble – Hearth and Home Technologies C-40 User Manual

Page 27

Advertising
background image

November 11, 2008

Heatilator • Constitution EPA Fireplace • 480-1091C

Page 27

NAIL

FLASHING

PLATE

CHIMNEY

THIMBLE

EXTENSION

SCREW

FLASHING

THIMBLE

ADJUSTABLE

EXTENSION

HOLES

FLASHING

CHIMNEY

FLASHING

PLATE

NAIL

THIMBLE

SCREW

THIMBLE

EXTENSION

B. SL-300 Series Ceiling/Roof Thimble

1. Locate the point where the chimney will exit the roof by

plumbing down to the center of the chimney. Lay out, cut

and frame a 14-1/2 in. (368 mm) square opening (measured

on the horizontal) through the ceiling and roof structure.

Consult local codes for framing details.

2. The thimble must extend completely through the roof struc-

ture shielding combustible materials. Five location holes

have been provided to allow for a variety of ceiling/roof

thicknesses. A Thimble Extension is required when the

ceiling/roof thickness exceeds 12-1/2 in. (318 mm). The

extension should overlap the thimble one inch.

3. To attach the extension to the thimble, drill 1/8 in. (3 mm)

holes through the outer shield of the thimble using the

predrilled holes in the extension as guides. Attach the

extension to the thimble using the screws provided with

the extension.

4. Install the thimble assembly and nail it securely to the fram-

ing members.

5. Center the flashing over the chimney and nail it to the roof

using the Stormguard nails provided. Keep gaps between

the flashing plate and the roof to a minimum. Caulk the flash-

ing plate and roof junction as well as the vertical seam on

the flashing. All nail heads must be caulked with a roofing

sealant.

6. Finish assembling the chimney storm collar and termina-

tion cap following the installation instructions provided with

them.

CHIMNEY

FLASHING

PLATE

JOISTS

NAIL

THIMBLE

FLASHING

Figure 27.1 Installing Part: 12966A, Configuration 1

Figure 27.2 Installing Part 12966A, Configuration 2

Figure 27.3 Installing Part 12966A Configuration 3

NOTE: REQUIRED for manufactured homes with vaulted

ceilings.